Hi Caltunas,
I saw your old post on the forums about th BEU bEST OpenAPI Starter Kit back in 2019.
I too would like to develop for the Konica...
User Profile
Collapse
-
Thanks Synthohol, I was kind of hoping I could macro actually sending the scan or changing the save location.
It seems it wont let me connect more... -
Keyboard HID Function Reference
When a USB keyboard is attached to a bizhub, is there any documentation for other functions that can be triggered or controlled?
For instance, could... -
Think i sorted this one, turns out Switch 105 Bit 1 - "Enables the function that targets CMK for gradation correction to fix issues where images...Leave a comment:
-
Any guesses what DipSW 189 Bit 1 does?
The "V2" FUM algorithm does?
Fumbling Under Machinery?Leave a comment:
-
Gradation Result All 0 for Yellow only in Printer Gradation fine in Copy Gradation
Although no error codes are being thrown I'm findign that at 600dpi and 1200dpi the gradation yields all 0's only for the yellow adjustment result. All... -
Resurrecting this old thread, I'm curious how techsxge went with modding the firmware?
I've noticed that the sometimes the @VER in the reset...Leave a comment:
-
Thanks Synthohol!
I've managed to unsilly-fy it somewhat and she's functional again.
I've noticed that the C759 has a CCD-ID table configurable...Leave a comment:
-
Same thing when scanning to usb, except a little worse because not all the same options are there.
To make matters worse, i've done gone...Leave a comment:
-
This occurs both for the original on glass & when scanning via the ADF.
It's better when turning off compression at maximum resolution using...Leave a comment:
-
Not scanning lighter colours
I've got a C458 that's dropping light colours when scanning, but prints perfectly well.
The issue seems to effect both the front and back scan,... -
Probably a silly question, but should is function version 4.2 a higher function version than 7?
I'm on the C458 also, with the GCQ-Y2 firmware....Leave a comment:
-
Did you find much of an improvement?
A lot of the linux libraries used for scanning seem to change quite rarely, so I doubt there is much of a physical...Leave a comment:
-
Hmm for some reason it doesn’t seem to accept any hex switch change to 100. Maybe needs to be in a different function mode or OEM mode somehow?
...Leave a comment:
-
Multibit SW
Looking at the software switches for the Zeus S series line, it seems that SW100 has four very different positions, which might all be beneficial to apply.... -
Multibit software switch
Looking at the software switches for the Zeus S series line, it seems that SW100 has four very different positions, which might all be beneficial to apply.... -
I've watched all his videos last week & thought he would be great too. But his website is down and looks like they're an office national franchise...Leave a comment:
-
C458 i-Option Function Codes Token LK-110 LK-108
I'm in the process of trying to restore the OCR functionality to a C458 on a second hand machine.
The device still has user accounts with the OCR...Last edited by systemnova; 3 weeks ago.
No activity results to display
Show More
Leave a comment: