I am Working on a Xerox DC250 color copier. Having image problems. 1/4 of the page the image is blurred. When printing single colored images, K and C have the mentioned problem. M and Y is fine, Full image print out is perfect.
I tested the following to be okay i.e IIT, 4 Drums, 4 rails, lift assembly, 4 developers and IBT assembly. No frame distortions.
I traced the problem down to the ROS assembly. When I replaced it with a known good one...Bingo everything was perfect!!
Question: Can this ROS assembly be adjusted by DC685 Max setup?? or do I need to replace it. Unfortnately during my training with Xerox, the trainer never showed us how to carry out the ROS adjustments.
Anyone has experience with this? please let me know. Thanks.
I tested the following to be okay i.e IIT, 4 Drums, 4 rails, lift assembly, 4 developers and IBT assembly. No frame distortions.
I traced the problem down to the ROS assembly. When I replaced it with a known good one...Bingo everything was perfect!!
Question: Can this ROS assembly be adjusted by DC685 Max setup?? or do I need to replace it. Unfortnately during my training with Xerox, the trainer never showed us how to carry out the ROS adjustments.
Anyone has experience with this? please let me know. Thanks.