Fs-2126 parts waste toner assy & case spacers
We just went thru did update parts on a 2126 including the parts waste toner assy. It says not use new unit and spacers because new waste toner assy modified... -
Canon IR2016i lite copies
Hi Guys,
We have a Canon IR2016i with lite streaks throughout copies.
Skyshot copies show lite and blank streaks, I replaced drum and cleaned... -
Stray Toner marks on IR1024
I have a weird problem that most technicians have failed to solve. The drum attracts stray toner on the left hand side and transfers to paper. See attached... -
C.6501 - Magenta quality problem -
Hello guy's,
We have a quality problem with C.6501 . The engine has 1900K.
You can see the problem on PDF.
... -
Old EP 1085 with occasional blurry copy
I know it's old, but I need it fixed. I replaced the clutches and cleaned and still gets random blurry line on copy. Any thoughts?
Thanks in ad... -
MX3100 yellow drum damaged
Have a problem where the OPC film is peeled off of the yellow drum. Unit has 3300 color prints on it. Here are a couple of images. I had a drum with me... -
IR3045 image fading
Hi. kindly advise me how to isolate my problem of ir3045. After mounding the Hopper assembly the image is fading. Due to the error code of E20 I... -
Black copies ... well sort of.
I think this qualifies as a heads up. I suppose I ought to throw in all the embarrassing details.
The machine is an iR3570.
It started...Last edited by blackcat4866; 04-13-2013, 04:46 AM. -
Panasonic dp's black lines?
I have sevral panasonic dp copiers that will give speratic black wispy lines threw out copy. They come an go no rime to why..looks kinda like a bias... -
T1100 Wide Format cutter problem
Just replaced the carriage belt in a T1100, and now the cutter is not working correctly. It does not cut cleanly, it "pushes" up... -
Bizhub 250 second side poor quality
Simplex is perfect. Replaced drum unit with new and same result. Is this a bad dv unit?
kelly -
bh 222 with broken mylay on developer unit.
Rear side mylar on mag roller keeps breaking. Happened on two units, about 45K each. I replaced transfer roller assembly and that did not help. The mylar... -
MP 2550 with DF3030 dog ears originals when scanning
Yes I have seen the other posts regarding this problem but I still have a couple of questions.
On the left hinge which springs need stretching and... -
bizhub 223 deveroper unit question
so I went and replaced developer and drum unit today on a machine. everything worked great but I did notice lines on the copies before and after the... -