User Profile
Collapse
-
What error code? -
You can tape over the toner add hole on both dev units and swap yellow and magenta. Run a test target 58 at 128 density of yellow and all other density...Leave a comment:
-
So you moved the magenta drum and the problem stayed in the magenta? I would only move the magenta drum first to see if it moves with the drum. if you...Leave a comment:
-
-
two things if the belt is to far to one side when you first turn on it will give this code and if there are small groves on the steel pin that rides...Leave a comment:
-
Also used to polish drums with brasso , there's no telling what chemicals/metals are in my body👍 5Leave a comment:
-
I've replaced the Memory Board on several machines to resolve this issue part number A6DTR70300👍 1Leave a comment:
-
This may help , If not I know its somewhere in the admin settings
To customize the function keys on a Konica Minolta Bizhub C558, you can do the...👍 1Leave a comment:
-
Did you replace the entire drum units or just the drums? If you replaced the entire drum units it looks like you have a defective magenta drum unit....👍 1Leave a comment:
-
did anything change on the customers network? If it was reporting meters then just stopped its possible that the gateway changed ....👍 1Leave a comment:
-
Not ignorant , we all make mistakes. Glad you figured it out. Thanks for the update. Also ask your friend for the PDF and all the other firmware that...Leave a comment:
-
send me your email and I will send movie date or if you have access to Konica Minolta look for movie data in special firmware...Leave a comment:
-
-
-
For the CC180 it means the loadable device driver needs to match the firmware. You could try getting the loadable device driver for the firmware you put...Leave a comment:
-
C-3102 error code and a noise
C-3102 error code
"CAUSE: Heating roller rotation sensor (PS37) may misdetect
...Leave a comment:
-
Make sure you have the correct firmware. There is firmware for machines with or without memory. There was a bulletin a while back telling how to tell...Leave a comment:
-
P8 Firmware is the most stable with papercut. Just be sure to set SW 25 to Hex 30...Leave a comment:
-
-
I think there is an admin setting for this. You could try exporting all the settings , minus the security setting, from working machine into this machine...Leave a comment:
No activity results to display
Show More
Leave a comment: